Required network ports for DFWorks servers.

print
Product Feature: Platform

Operating System: Windows Server 2003/Windows Server 2008

Database: Oracle 9i/Oracle 11g

Configuration: All
The following chart list all of the network ports which must be enabled for DFWorks servers.
 

Required Ports on DFWorks Servers

#

Server

Protocol  

Port

Configurable

Purpose

1Web ServerHTTP80NoAccept connections from remote computers to DFWorks Web Server. Once a device is connected, it will send the requested web pages to the remote device, and when done disconnect the connection.
2Web ServerHTTPS443NoAccept connections from remote computers to DFWorks Web Server using SSL. Once a device is connected, it will send the requested web pages to the remote device, and when done disconnect the connection.
3Web ServerTCP5001NoReceives data from RSM Client.
4Web ServerTCP7277NoReceives data from Site View Clients.
5Web Server HTTP8080YesReceives requests from Workflow View, Shop Floor Control View & Funds View Applets This port is configurable through install sheild from DFWorks 2.8.37 onwards.
6Application ServerTCP5005NoXML Message Handler.
7Application Server 8005NoThis is required to shut down Tomcat (internal to Tomcat Server).
8Application ServerTCP8085YesReceives data from Flex Server.
Receives data from Tomcat Server.
This port is configurable through install sheild from version 2.8.37 onwards.
9Application ServerHTTP8086NoRestricts multilpe instnaces of Mailpiece File Importer.
10Application ServerTCP9010NoThis is required for performing funds refill on 6500 series meters.
11Application ServerTCP9085NoActs  as a proxy server. Receives messages from
UIC and forwards those messages to center. Similarly
it listenes for messages from the center and forwards
them to UIC. Required for performing Meter Refills.
12Application ServerHTTP9095NoDFWorks Task Schedular.
13Application ServerHTTP9099NoTomcat Health Page.
14Application ServerHTTP51000NoTomcat HTTP Port (internal to Tomcat Server).
15Database ServerTCP1521NoDFWorks Applications (UdhWeb Server) running on Web Server connects to database.
DFWorks Applications & Tomcat Server running on Application Server connects to database.
DC Datapump server connects to DFWorks Database Server.
16TCP / HTTP1158 HTTP port for Oracle Enterprise Manager Database.
17HTTP3938 HTTP port for Oracle Enterprise Management Agent.
18TCP5520 RMI port for Oracle Enterprise Manager Database.
19TCP5540 JMS port for Oracle Enterprise Manager Database Control.

 


Required Ports on Other Servers

#

Server

Protocol  

Port

Configurable

Purpose

1RSM Client ServerTCP9000NoUdhWeb Server communicates with RSM Client Server.
2Customer E-Mail ServerTCP25NoUdhWeb Server communicates with Customer E-Mail Server to send Alerts & Dispatches.
DFWorks Database Server communicates with Customer E-Mail Server to send Alerts & Dispatches.
3OnRoute HTTPS443YesDFWorks Application Server communicates with OnRoute system.
4Postage By Phone Center TCP80NoEither requires AT&T Global network or Application server direct access to World Wide Web Required for performing Meter Refills (It has been previously brought to our attention that some firewalls see these messages as Virus and filters them out. This needs to be configured in a firewall vendor proprietary format so that this does not happen).
5UICTCP6996NoRequired for performing Meter Refills.                                                                           Required for registering Meter Status messages from UIC.
6UICTCP6998NoTCP Required for receiving Meter Status messages from UIC.
7UICTCP7998NoRequired for receiving Meter Status messages from UIC for TestUIC tool.
8E2 Vault 6003NoRequired to view Statement.











 

UPDATED: March 20, 2015