Error 03114100E4 (PE0 Not Ready) on the SendPro MailCenter, SendPro P Series or Connect+ Series

Products affected: SendPro® MailCenter, SendPro® P Series, Connect+® Series

Issue

The error 0311-41-00E4: PE0 Not Ready appears and the meter does not print.

Cause

The print engine firmware may need to be updated.

Resolution

Solution 1: Check for updates

Download and install any software updates that may be available for your meter.

  1. Select Rates & Updates from the Home screen.
  2. Select Download Updates if updates are available. If no updates are available, proceed to Solution 2.
  3. Select Install Updates.

If you still have an issue, go to Solution 2.

Solution 2: Restart your meter

Follow these steps for a safe restart:

  1. Select the Gear icon from the lower right corner of the Home screen.
  2. Select Shut Down from the menu.
  3. Select Shut Down on the pop-up.
  4. Wait for the screen to go black and the blue light on the front to go out. This may take several minutes.
  5. After the meter has been off for 10 seconds, press the power button to turn it back on.

UPDATED: November 11, 2026