Resolve Error E16 on Relay 1000 & DI200 OfficeRight Inserting System
Learn how to resolve error E16 on the DI200 OfficeRight Inserting System. Intelligent nip sensor S06 MADE to nesting sensor S07 MADE exceeds 2 seconds.
Products affected: Relay™ 1000 and DI200
Issue
The display shows error E16 and the machine will not run.
Cause
There is a material jam between feeder B and C.
Resolution
Check for obstructions in the paper path:
- Open jam releases E and D and remove any material.
- Close the jam releases and press Trial Piece.